Master the NS0-520 NetApp Certified Implementation Engineer - SAN. ONTAP content and be ready for exam day success quickly with this Exambible NS0-520 simulations. We guarantee it!We make it a reality and give you real NS0-520 questions in our Network-Appliance NS0-520 braindumps.Latest 100% VALID Network-Appliance NS0-520 Exam Questions Dumps at below page. You can use our Network-Appliance NS0-520 braindumps and pass your exam.
Online Network-Appliance NS0-520 free dumps demo Below:
NEW QUESTION 1
You install an ASA AFF A400 system with 32 GB FC SFP+ modules in port 0e and 0f. After creating the SVM and configuring the FCP protocol, the physical port stays offline. Referring to the exhibit which statement is correct?
- A. The current type of the ports must be configured as an initiator
- B. The current mode to the ports must be configured as an FC port
- C. The current mode for the ports must be set as an NVMe/FC port
- D. The admin status is manually set to down
Answer: B
Explanation:
Before using your UTA ports on a FC infraestructure, you need to modify the current mode from CNA to FC. You need to set the ports offline before you modify that parameter.
You can find more information on this link:
http://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-E2CD31BE-28E
NEW QUESTION 2
What are two benefits of implementing VLANs for ISCSI configuration? (choose two)
- A. Reduced number of broadcast domains
- B. Increased performance
- C. Increased security
- D. Increased resiliency
Answer: AC
Explanation:
When you implement VLANs in large IP network infrastructures, you derive the following benefits: Increased security.
VLANs enable you to leverage existing infrastructure while still providing enhanced security because they limit access between different nodes of an Ethernet network or an IP SAN.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-C5288E55-DA
NEW QUESTION 3
Referring to the exhibit, which two pairs of ports are currently configurable as FC SAN LIFs? (Choose two.)
- A. 01b, 0h
- B. 01a, 0g
- C. 01a, 0h
- D. 01b, 0g
Answer: D
NEW QUESTION 4
While changing the network connections on your ONTAP cluster from twinax to fiber, the ports experience network connectivity issues. You want to verify which speeds the ports support and ensure that you
have supported transceivers. In this scenario which two actions would accomplish this task (choose two)
- A. Use hardware universe to determine the supported transceivers
- B. Use the interoperability matrix tool to determine the supported port speeds
- C. Use hardware universe to determine the supported port speeds
- D. Use the interoperability matrix tool to determine the supported transceivers
Answer: AC
Explanation:
Hardware universe will show information about port speeds and transceiver compatbility You can find more information on this link: https://hwu.netapp.com/Resources/hwu_ug.pdf (page 73)
NEW QUESTION 5
You have finished deploying a Netapp AFF All SAN Array Cluster and want to test the persistent ports feature. In this scenario, how would you accomplish this task?
- A. Perform a takeover of a node
- B. Disconnect an FCP initiator port
- C. Disconnect an FCP target port
- D. Disable a SAN LIF
Answer: A
Explanation:
If we don't have OnCommand Insight, then we should not pull out a cable as test because it won't be detected properly.
Doing a planned takeover will meet the requirements asked. Table Description automatically generated
You can find more information on this link: https://www.netapp.com/pdf.html?item=/media/10379-tr4515.pdf&v=20217121554 (26)
NEW QUESTION 6
Which NetApp tool provides a detailed inventory of SAN components?
- A. Active IQ OneCollect
- B. Interoperabilty Matrix Tool
- C. Active IQ config advisor
- D. Hardware Universe
Answer: A
Explanation:
ActiveIQ OneCollect is a tool from NetApp that will create an inventory of your environment that will include hosts, switches and storage and validate it against the IMT (Interoperability Matrix Tool).
NEW QUESTION 7
An administrator wants to implement FCoE for connectivity of an AFF A200 using VLAN 3011 for fabric traffic across VSAN 11. When configuring the Nexus switches for FCoE connectivity, which two actions are required? (Choose two.)
- A. Create a new virtual FC interface and bind the physical interface to it.
- B. Add the virtual interface to the VSAN.
- C. Create a port channel and add all of the physical network ports that will have FCoE LIFs.
- D. Add the adapter MAC address to the network port configuration where the node is connected.
Answer: BC
NEW QUESTION 8
You want to connect a NetApp AFF A700 to a 32 Gb FC switch. The ports need to connect at 32 Gb speed. In this scenario, which statement is correct?
- A. The AFF A700 includes FC ports natively on the controller.
- B. The AFF A700 includes an additional FC I/O module that is already populated in each controller.
- C. You need to purchase a two-port or four-port unified I/O module that enables FC and Ethernet connectivity.
- D. You need to purchase a two-port or four-port FC I/O module.
Answer: C
NEW QUESTION 9
Exhibit.
An administrator is configuring FCoE on Cisco Nexus switches for a new AFF A200 ONTAP cluster. The administrator executes the commands shown in the exhibit to create the necessary network configuration.
Which VLAN is responsible for controlling the FCoE traffic on the new interface?
- A. 3011
- B. 23
- C. 11
Answer: B
NEW QUESTION 10
What is the recommended minimum of data LIFs per node for iSCSI in a dual-fabric configuration with four SVMs?
- A. 8
- B. 12
- C. 16
- D. 4
Answer: A
Explanation:
Reference: https://docs.netapp.com/ontap-9/topic/com.netapp.doc.dot-cm-sanconf/GUID-650DC466-CA3F
FCEEB52E7.html (6th bullet)
NEW QUESTION 11
A customer has an FC host that needs to be attached to the NetApp AFF A700 dual controller storage cluster. To accomplish this task, which three steps should the customer perform? (Choose three.)
- A. Configure the FCP service for the node that has the LUN that is being accessed.
- B. Confirm that the FC HBA driver and firmware is supported according to the Interoperability Matrix Tool (IMT)
- C. Configure portsets to support the availability of multiple paths.
- D. Configure an igroup with the WWPN from the host initiator for LUN access.
- E. Confirm that the switch firmware is supported according to the Interoperability Matrix Tool (IMT).
Answer: CDE
NEW QUESTION 12
You are planning to set up a new SAN with an AFF A300 2-node switchless cluster. Your SAN fabric will consist of Cisco MDS9148s switches.
According to NetApp best practices, which two actions would be required to accomplish this task? (Choose two.)
- A. Set the switchport speed setting to 16 Gb.
- B. Use single initiator, multiple target zoning.
- C. Use multiple initiator, single target zoning.
- D. Set the switchport speed to auto negotiate.
Answer: BD
Explanation:
Reference: https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-mcc-inst-cnfg-fabric% 2FGUID-DA51E013-0C96-4D55-9E35-39CDE07082E9.html
NEW QUESTION 13
Referring to the exhibit, which security feature would guarantee that the host A system that is mapped to LUN XYZ on the NetApp storage system is the only host that access the LUN?
- A. igroup setup with the IQN of the ISCSi software initiator on Host A.
- B. CHAP configured on HOST A and the NetApp Storage System
- C. igroup setup with no IQNs
- D. IPsec configured on both host A and the NetApp Storage System
Answer: B
Explanation:
Graphical user interface, text, application, email Description automatically generated
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-3FC8A37A-FFC
NEW QUESTION 14
Which topology allows for guaranteed maximum network performance for iSCSI?
- A. isolated VLAN network
- B. MetroWAN network
- C. direct connect
- D. WAN network
Answer: C
NEW QUESTION 15
You are troubleshooting high CPU use on a FAS8200 with all SAS HDDs. You have SAN hosts with LUNs in a volume named vol1. You want to reduce CPU use and maintain storage efficiencies.
Referring to the exhibit which three actions will accomplish this task? (Choose three.)
- A. Disable compression.
- B. Enable cross-volume deduplication.
- C. Disable inline deduplication.
- D. Enable post process deduplication.
- E. Enable data compaction.
Answer: CDE
NEW QUESTION 16
......
100% Valid and Newest Version NS0-520 Questions & Answers shared by Certleader, Get Full Dumps HERE: https://www.certleader.com/NS0-520-dumps.html (New 234 Q&As)